EN IEC 62984-2-2020 pdf download
EN IEC 62984-2-2020 pdf download.High-temperature secondary batteries – Part 2: Safety requirements and tests (IEC 62984-2:2020).
This part of IEC 62984 specifies safety requirements and test procedures for high-temperature batteries for mobile and/or stationary use and whose rated voltage does not exceed 1 500 V.
This document does not cover aircraft batteries, which are covered by IEC 60952 (all parts), and batteries for the propulsion of electric road vehicles, covered by IEC 61 982 (all parts).
NOTE High-temperature batteries are electrochemical systems whose cells’ internal minimum operating temperature is above 1 00 °C.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60068-2-1 8:201 7, Environmental testing – Part 2-18: Tests – Test R and guidance: Water
IEC 601 1 2, Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60204-1 , Safety of machinery – Electrical equipment of machines – Part 1: General requirements
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 60664-1 :2007, Insulation coordination for equipment within low-voltage systems – Part 1: Principles, requirements and tests
IEC 61 1 40:201 6, Protection against electric shock – Common aspects for installation and equipment
IEC 61 508 (all parts), Functional safety of electrical/electronic/programmable electronic safety-related systems
IEC 62984-1 :2020, High-temperature secondary batteries – Part 1: General requirements
3 Terms, definitions, symbols and abbreviated terms
For the purposes of this document, the terms and definitions given in IEC 62984-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1 Battery safety
3.1.1 rated insulation voltage
rated value of the RMS withstand voltage assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation
Note 1 to entry: The rated insulation voltage is not necessarily equal to the rated voltage of equipment which is
primarily related to functional performance. [SOURCE: IEC 60050-31 2:201 4, 31 2-06-02]
3.1.2 functional insulation
insulation between conductive parts, necessary for the proper functioning of the equipment
[SOURCE: IEC 60050-1 95:1 998, 1 95-02-41 ]
3.1.3 supplementary insulation
independent insulation applied in addition to basic insulation in order to provide protection against electric shock in the event of a failure of basic insulation
[SOURCE: IEC 60050-1 95:1 998, 1 95-06-07, modified – “for fault protection” has been replaced by “in order to provide protection against electric shock in the event of a failure of basic insulation”.]
3.1.4 reinforced insulation
insulation of hazardous-live-parts which provides a degree of protection against electric shock equivalent to double insulation
[SOURCE: IEC 60050-1 95:1 998, 1 95-06-09, modified – The note has been omitted.]
3.1.5 double insulation
insulation comprising both basic insulation and supplementary insulation
Note 1 to entry: Basic and supplementary insulation are separate, each designed for basic protection against electric shock.
[SOURCE: IEC 60050-1 95:1 998, 1 95-06-08, modified – The note to entry has been added.]
3.1.6 extra-low voltage
ELV voltage not exceeding the maximum value of the prospective touch voltage which is permitted
to be maintained indefinitely under specified conditions of external influences [SOURCE: IEC 61 1 40:201 6, 3.26]EN IEC 62984-2 pdf download.