IEC 62776-2014 pdf download
IEC 62776-2014 pdf download.Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications.
This International Standard specifies the safety and interchangeability requirements, and the exchange operation together with the test methods and conditions required to show compliance of double-capped LED lamps with G5 and G1 3 caps, intended for replacing fluorescent lamps with the same caps, having:
– a rated power up to 1 25 W;
– a rated voltage of up to 250 V.
Such LED lamps are designed for replacement without requiring any internal modification of the luminaire.
The existing luminaires, into which the double-capped LED lamps are fitted, can be operated with electromagnetic or electronic controlgear.
The requirements of this standard relate only to type testing.
Recommendations for whole product testing or batch testing are given in Annex A.
NOTE 1 Where in this standard the term “lamp(s)” is used, it is understood to stand for “double-capped retrofit LED lamp(s)”, except where it is obviously assigned to other types of lamps.
This standard does not cover double-capped conversion LED lamps where modification in the luminaire is required. The requirements in this standard are given for general lighting service (excluding for example explosive atmospheres). For lamps for other applications additional requirements may apply.
NOTE 2 This standard includes photobiological safety.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60061 -1 , Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 1: Lamp caps
IEC 60061 -3, Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 3: Gauges
IEC 60061 -4, Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 4: Guidelines and general information
IEC 60081 , Double-capped fluorescent lamps – Performance specifications
IEC 601 55, Glow-starters for fluorescent lamps
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62504, IEC 62031 as well as the following apply.
3.1 double-capped retrofit LED lamp
tubular LED lamp which can be used as a replacement for double-capped fluorescent lamp without requiring any internal modification in the luminaire and which, after installation, maintains the same level of safety of the replaced lamp in the luminaire
Note 1 to entry: The replacement of a glow starter according to IEC 601 55 with LED replacement starter having the same dimensions and fit, for the correct functioning of the double-capped LED lamp is not considered as a modification to the luminaire.IEC 62776 pdf download.