IEC 62236-4-2018 pdf download
IEC 62236-4-2018 pdf download.Railway applications – Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus.
This part of IEC 62236 applies to signalling and telecommunication apparatus that is installed inside the railway environment. Signalling and telecommunication apparatus mounted in vehicles is covered by IEC 62236-3-2:201 8, signalling and telecommunication apparatus installed inside the substation and connected to substation equipment is covered by IEC 62236-5:201 8.
This document specifies limits for emission and immunity and provides performance criteria for signalling and telecommunications (S&T) apparatus (including power supply systems belonging to S&T) which may interfere with other apparatus inside the railway environment, or increase the total emissions for the railway environment and so risk causing Electromagnetic Interference (EMI) to apparatus outside the railway system.
The requirements specified in this document apply for:
– vital equipment such as interlocking or command and control,
– apparatus inside the 3 m zone,
– ports of apparatus inside the 1 0 m zone with connection inside the 3 m zone,
– ports of apparatus inside the 1 0 m zone with cable length > 30 m.
Other apparatus not covered by at least one of these given cases is in compliance with IEC 61 000-6-2.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirements in this document are not intended to be applicable to the intentional transmission from a radio- transmitter as defined by the ITU.
Immunity limits do not apply in the exclusion bands as defined in the corresponding EMC related standard for radio equipment.
This document does not specify basic personal safety requirements for apparatus such as protection against electric shock, unsafe operation, insulation co-ordination and related dielectric tests. The requirements were developed for and are applicable to this set of apparatus when operating under normal conditions. Fault conditions of the apparatus have not been taken into account.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.
For products in the scope of IEC 61 000-3-2, IEC 61 000-3-3, IEC 61 000-3-1 1 or IEC 61 000-3-1 2, the requirements of those standards also apply.
These specific provisions are used in conjunction with the general provisions in IEC 62236-1 .
The immunity and emission levels do not of themselves guarantee that the integration of apparatus will necessarily be satisfactory. The document cannot cover all the possible configurations of the apparatus, but the test levels are sufficient to achieve satisfactory EMC in the majority of cases.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 61 000-4-2:2008, Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
IEC 61 000-4-3:2006, Electromagnetic compatibility (EMC) – Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC 61 000-4-4:201 2, Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC 61 000-4-5:201 4, Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
IEC 61 000-4-6:201 3, Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61 000-4-8:2009, Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
IEC 61 000-6-2:201 6, Electromagnetic compatibility (EMC) – Part 6-2: Generic standards –
Immunity standard for industrial environments
IEC 61 000-6-4:2006, Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environments
IEC 61 000-6-4:2006/AMD1 :201 0
IEC 62236-1 :201 8, Railway applications – Electromagnetic compatibility – Part 1: General.IEC 62236-4 pdf download.