IEC 60404-7-2019 pdf download.Magnetic materials – Part 7: Method of measurement of the coercivity (up to 160 kA/m) of magnetic materials in an open magnetic circuit.
This part of IEC 60404 specifies a method of measurement of the coercivity of magnetic materials in an open magnetic circuit.
This document is applicable to all magnetic materials with coercivities from 0,2 A/m to
1 60 kA/m.
NOTE Examples of magnetic materials covered by this document are amorphous alloys, nanocrystalline alloys, all softmagnetic crystalline materials (e.g. Fe, FeSi-, CoFe- and FeNi-alloys), soft ferrites, hard metals, semi-hard magnetic alloys (e.g. FeCoTiAl-, FeCoV-, FeCrCo- and AlNiCo-alloys) [1 ] 1 .
Special precautions are to be taken in measuring coercivities below 40 A/m, in materials with high conductivity and in test specimens which have a shape different from ellipsoids (see Annex A).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
There are no normative references in this document.
3 Terms and definitions
For the purpose of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1 coercivity H cJ
value of the coercive field strength in a material when the magnetic flux density, magnetic polarization or magnetization is brought from saturation by a monotonically changing magnetic field to zero
4 Principle of the method If a magnetic test specimen is placed in a uniform and unidirectional magnetic field then it will distort this magnetic field unless a condition that no flux (additional to that previously carried by the air space it now occupies) enters or emerges from the test specimen. This condition represents a state of complete demagnetization which occurs when a demagnetizing coercive magnetic field strength is applied to the test specimen such that the magnetic polarization is zero [2].
The test specimen is magnetized to saturation (J s ) and then the magnetic field is reduced smoothly without interruption to zero (J r ). Afterwards the polarity of the magnetic field is reversed and a demagnetizing field is increased until the magnetic polarization of the test specimen is zero. The applied magnetic field strength required to achieve this condition is measured and defined as the coercivity H cJ of the test specimen (see Figure 1 ). A magnetic flux sensing probe enables the detection of the condition of no distortion of a uniform magnetic field by the test specimen and provides the means for determining the coercivity. For this measurement, the test specimen and the magnetic flux sensing probes are placed in an open magnetic circuit in the uniform and unidirectional magnetic field of a solenoid. The flux sensing probe should be placed as follows:
a) inside the solenoid, close to the end of the test specimen (Method A – Hall probe, see Figure 3), or
b) inside the solenoid, at a distance from the test specimen, depending on the size and permeability of the test specimen (Method A – differential fluxgate probe, see Figure 4), or
c) outside the solenoid (Method B – differential fluxgate probe, see Figure 5).
The solenoid and measuring equipment shall be connected as shown in Figure 2.IEC 60404-7 pdf download.