EN IEC 60966-1-2019 pdf download.Radio frequency and coaxial cable assemblies – Part 1: Generic specification – General requirements and test methods (IEC 60966-1:2019).
This part of IEC 60966 specifies requirements for radio frequency coaxial cable assemblies operating in the transverse electromagnetic mode (TEM) and establishes general requirements for testing the electrical, mechanical and environmental properties of radio frequency coaxial cable assemblies composed of cables and connectors. Additional requirements relating to specific families of cable assemblies are given in the relevant sectional specifications.
The design of the cables and connectors used will preferably conform to the applicable parts of IEC 61 1 96 and IEC 61 1 69 respectively.
NOTE 1 This document does not include tests which are normally performed on the cables and connectors separately. These tests are described in IEC 61 1 96-1 (all parts) and IEC 61 1 69-1 respectively.
NOTE 2 Wherever possible, cables and connectors used in cable assemblies, even if they are not described in the IEC 61 1 96 or IEC 61 1 69 series, are tested separately according to the tests given in the relevant generic specification.
NOTE 3 Where additional protection is applied to a cable assembly, the mechanical and environmental tests described in this document are applicable.
2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies.For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60068 (all parts), Environmental testing
IEC 60068-2-6, Environmental testing – Part 2-6: Tests – Test Fc: Vibration (sinusoidal)
IEC 60068-2-1 1 , Basic environmental testing procedures – Part 2-11: Tests – Test Ka: Salt mist
IEC 60068-2-1 4, Environmental testing – Part 2-14: Tests – Test N: Change of temperature
IEC 60068-2-27, Environmental testing – Part 2-27: Tests – Test Ea and guidance: Shock
IEC 60068-2-42, Environmental testing – Part 2-42: Tests – Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-68, Environmental testing – Part 2-68: Tests – Test L: Dust and sand
IEC 60068-2-78, Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady state
IEC 60332-1 -2:2004, Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame
IEC 6051 2-6-2, Connectors for electronic equipment –Tests and measurements – Part 6-2: Dynamic stress tests – Test 6b: Bump
IEC 6051 2-7-2, Connectors for electronic equipment – Tests and measurements – Part 7-2: Impact tests (free components) – Test 7b: Mechanical strength impact
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 60966-2 (all parts), Radio frequency and coaxial cable assemblies
IEC 60966-3 (all parts), Radio frequency and coaxial cable assemblies
IEC 60966-4 (all parts), Radio frequency and coaxial cable assemblies
IEC 61 1 69 (all parts), Radio-frequency connectors
IEC 61 1 69-1 :201 3, Radio-frequency connectors – Part 1: Generic specification – General requirements and measuring methods
IEC 61 1 96 (all parts), Coaxial communication cables
IEC 61 1 96-1 -1 1 9, Coaxial communication cables – Part 1-119: Electrical test methods – RF power rating
IEC 62037-2, Passive RF and microwave devices, intermodulation level measurement – Part 2: Measurement of passive intermodulation in coaxial cable assemblies IEC 621 53-4-6, Metallic cables and other passive components test methods – Part 4-6: Electromagnetic compatibility (EMC) – Surface transfer impedance – Line injection method
IEC 621 53-4-7:201 5, Metallic communication cable test methods – Part 4-7: Electromagnetic compatibility (EMC) – Test method for measuring of transfer impedance Z T and screening attenuation a s or coupling attenuation a C of connectors and assemblies up to and above 3 GHz – Triaxial tube in tube method.EN IEC 60966-1 pdf download.