AAMI IEC-80601-2-78-2020 pdf download
AAMI IEC-80601-2-78-2020 pdf download.Medical electrical equipment—Part 2-78: Particular requirements for basic safety and essential performance of medical robots for rehabilitation, assessment, compensation or alleviation.
Clause 1 of the general standard1 applies, except as follows:
201.1.1 Scope Replacement,’
This part of IEC 80601 applies to the general requirements for BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ROBOTS that physically interact with a PATiENT with an IMPAIRMENT to suppOrt or perform REHABILITATiON. ASSESSMENT, COMPENSATION Of ALLEVIATION related to the PATIENT’S MOVEMENT FUNCTIONS, as intended by the MANUFACTURER.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so, If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
NOTE See also 4.2 of the general standard,
This particular standard does not apply to
external limb prosthetic devices (use ISO 22523),
— electric wheelchairs (use ISO 7176 (all parts)),
diagnostic imaging equipment (e.g. MRI. use IEC 60601-2-33), and
personal care robots (use ISO 13482).
201.1.2 Object
Replacement:
The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for MEDICAL ROBOTS that physically interact with a PATIENT with an IMPAIRMENT, to support or perform REHABILITATION, ASSESSMENT, COMPENSATION or ALLEVIATION related to the PATIENT’S MOVEMENT FUNCTIONS.
201.1,3 Collateral standards
Addition:
I The general standard is IEC 60601-1:2005 and IEC 60601-1:2005IAMD1 :2012, Medical electrical equipment — Part 1: General requirements for basic safely and essential performance.
This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard.
IEC 60601-1-2:2014. IEC 60601-1-6:2010 and IEC 60601-1-6:2O1OIAMD1:2013. IEC 60601-1-8:2006 and IEC 60601- 1-8:2006/AMD1:2012. IEC 60601-1.10:2007 and IEC 60601-1-10:2007IAMD1:2013, and IEC 60601-1.11:2015 apply as modified in Clauses 202, 206, 208, 210 and 211 respectively. IEC 60601-1-3 and IEC 60601-1-12 do not apply. AJI other published collateral standards in the IEC 60601-1 series apply as published.
201.1.4 Particular standards
Replacement:
In the IEC 60601 series, particular standards may modify, replace or delete requirements contained in the general standard and collateral standards as appropriate for the particular ME EQUIPMENT Under consideration, and may add other BASIC SAFETY and ESSENTIAL PERFORMANCE requirements.
A requirement of a particular standard takes priority over the general standard.
For brevity, IEC 60601-1:2005 and IEC 60601-1 :2005/AMO1 :2012 are referred to in this particular standard as the general standard. Collateral standards are referred to by their document number.
The numbering of clauses and subclauses of this particular standard corresponds to that of the general standard with the prefix “201” (e.g. 201.1 in this document addresses the content of Clause 1 of the general standard) or applicable collateral standard with the prefix “20x” where x Is the final digit(s) of the collateral standard document number (e.g.
202.4 in this particular standard addresses the content of Clause 4 of the 60601-1 -2 collateral standard, 203.4 in this particular standard addresses the content of Clause 4 of the IEC 60601-1-3 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words:
“Replacemenf means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this particular standard.
“Addition” means that the text of this particular standard is additional to the requirements of the general standard or applicable collateral standard.
“Amendmenf’ means that the clause or subclause of the general standard or applicable collateral standard is amended as Indicated by the text of this particular standard.
Subclauses. figures or tables which are additional to those of the general standard are numbered starting from 201.101.
However, due to the fact that definitions in the general standard are numbered 3.1 through 3.147, additional definitions
In this document are numbered beginning from 201,3.201. Additional Annexes are lettered AA, BB. etc., and additional
items aa), bb), etc.
Subclauses. figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where “x” is the number of the collateral standard, e.g. 202 for IEC 60601-1-2, 203 for IEC 60601-1-3, etc.
The term “this document” is used to make reference to the general standard, any applicable collateral standards and this particular standard taken together.
Where there is no corresponding clause or subclause in this particular standard, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect Is given in this particular standard.AAMI IEC-80601-2-78 pdf download.